Commercial vessels
Green control technology, easy & intuitive operation,
global service & support
The world is facing a climate emergency, and greenhouse gas emissions are at the heart of the issue. Like many other industries, the marine sector is embracing its important role and is changing fast. The selection of solutions and approaches is growing every day, and there is no global standard.
Propulsion and power systems are evolving, with a wide range of low-emission propulsion technologies and power bus architectures. Yet, despite the steps being made to reduce emissions and contribute to the green transition, safety remains the number one priority at sea. Shipowners and operators must work towards a double target: reduced emissions and improved safety.
Check out the application examples below to see some of the possibilities you get with DEIF expertise and devices.
Full range of devices
We offer the devices you need to build safe, reliable, and robust control solutions for commercial vessels: power management controllers such as the PPM 300 and PPU 300; PLCs including the AMC 300 and AMC 600; robust medium voltage relays; cutting-edge bridge instrumentation including navigational instruments with customisable indicators; wind sensors, rudder systems, and switchboard equipment; and the Blueflow system which helps you save fuel by optimising manoeuvres at sea. And much more!
Protection & power management PPM 300 PPM 300
- Synchronization
- Marine certified Power Management - ABP: Advanced blackout prevention (32dg)
- PLC logic
- Engine and Generator protection
- Engine CANbus
- Rear mount
- Flexible Hardware
- Additional I/O racks (9 racks)
- Ethernet Ring connection for Power management
- Redundant breaker feedback
- Colour Display
- Emulation
- Marine approval
- Heavy consumer
- Fast load reduction
- Fuel optimisation
Advanced Programmable Controller AMC 300
- Fully production tested control system units
- Designed for a lifetime no less than 10 years @ 40 ºC
- Suitable for Offshore, Marine and near shore environments
- Superior robustness to vibrations, bumps and shocks
- Better ESD protection, Surge protection of I/O and Power supply
- Warranty: 2 years (not including wearable parts) with option to 3 years.
- Core specifications:
- Cold start-up/Operating temperature: -40 to 70 °C
- Storage temperature: -40 to 85 °C
- Climate: 55 °C 97 % RH condensing
- Altitude: < 4000 m
- Vibration : 2.1 g (3.2 to 50 Hz) 1.0g (13.2 to 100 Hz)
- Shock: 50 g, 11 ms, half sine
- Bump: 25 g, 6 ms, half sine
- Multifunction I/O modules with 24V DC Digital Inputs, Digital Outputs, Relay Outputs, Voltage / Current Analogue Inputs, Thermocouples, PT100/1000 inputs, Frequency Counter inputs, PWM outputs.
- Direct 3-phase 690 V voltage and 1/5A current measurement with class 0.5 Power measurement
- Modular I/O concept with distributed I/O nodes based on Standard EtherCAT and supporting EtherCAT cable redundancy
- CAN/CANopen, TCP/IP, RS-422/485 serial communication interfaces
- Operating system software with fail-safe update
- DEIF In-house maintained OS
- Real-time Patched Linux
- Discover the device via hostname (mDNS services)
- Web based configuration
- Simplified update procedures (no special tools, same for OS and firmware)
- Secured Certificated based access by standard protocols
- Customer manages all users, rights and credentials
- Network config on build-in 5 port switch (VLANs)
- Network Time protocol support as both Client and Server
- Fail-safe system software start up with two OS images (active and fault-back)
- Fault-tolerant file system
- Open software development with Linux, CODESYS V3 (IEC 61131-3)
- Regular updates to newest CODESYS V3.5 Service Packs
- Modbus TCP Client and Server library
- OPC UA Server (Open62541) library
Programmable automation controller with EtherCAT based I/O AMC 600
General specifications
- Cold start-up/Operating temperature: -40 to 70 °C
- Storage temperature: -40 to 85 °C
- Climate: 55 °C 97 % RH condensing
- Altitude: < 4000 m
- Vibration : 2.1 g (3.2 to 50 Hz) 1.0g (13.2 to 100 Hz)
- Shock: 50 g, 11 ms, half sine
- Bump: 25 g, 6 ms, half sine
- New platform formfactor – height of just 122 mm; depth 114 mm
- Design lifetime of no less than 10 years at 40 ºC surrounding temperatures
- Backplane mounted rack ensuring stable inter-module communication during operation in the entire products lifetime
- Fully production tested control system units lowering in-sourcing costs for series production at customer
- Suitable for Stationary, mobile, wind turbine retrofit
- Increased mechanical robustness
- Increased electrical protection levels ; ESD up to 6kV, up to 4kV on power inputs and 2kV on all signal and communication power for fast transients protections
- Designed the input circuits with protections against failure connections
- Cold start up in very low-temperature without pre-heating
- Proven electronics design for demanding condensing climates
- Built-in standard EtherCAT as native communication protocol for use as distributed I/O
- High density IO modules
- 24V DC Digital Inputs, Digital Outputs, Voltage / Current Analogue Inputs, PT-100 inputs
- Condition monitoring modules with High Frequency Analogue Inputs
- Support for most widely used fieldbusses : CAN/CANopen, PROFINET, RS-422/485, TCP/IP ( OPC UA, Modbus TCP etc. )
- Warranty: 2 years (not including wearable parts) with option to 5 totally years
System software, Operating System and Programming
- Operating system software with fail-safe update
- DEIF In-house maintained OS
- Real-time Patched Linux
- Web based configuration
- Simplified update procedures (no special tools, same for OS and firmware)
- Secured Certificated based access by standard protocols
- Customer manages all users (Operator, Service and Administrator), rights and credentials
- Network configuration of the 2 independent network interfaces.
- Network Time protocol support as Client
- Fail-safe system software start up with two OS images (active and fault-back)
- Fault-tolerant file system
- Web based configuration
- User management
- Programming with CODESYS V3.5 and C/C++
- Regular updates to newest CODESYS V3.5 Service Packs
- Secure Web based visualization
Medium Voltage Relay MVR-200 series
- Programmable logic
- Fast and easy commissioning and service with front communication port and intuitive software
- Password-protected user levels
- Individual voltage and current harmonics up to 31st
- Redundant Ethernet with Modbus TCP
- RS-485 Modbus RTU communication
- IEC 60870-5-104/103/101 communication
- IEC 61850 communication (incl. HSR, PRT, PTP acc. IEEE 1588) and GOOSE
- On-site replaceable spare part modules
- Class 0.5 power and energy measurement (Class 0.2S optional)
- Conformal Coating available for all devices
- Marine type approval by major class societies
Dedicated to supporting you through changing times
As you work towards this double target, you can save time and effort by working with an industry partner capable of developing and delivering solutions that help you fulfil your operational requirements.
Renowned for setting some of the highest quality standards in power control, management, and protection, we at DEIF enable you to take part in the green transition. Based on decades of know-how, our systems and devices ensure not only optimum reliability and safety – regardless of conditions – but also forward-thinking efficiency that supports compliance with global regulations and your goals towards a decarbonised future.
Whether we talk container ships, Ro-Ro vessels, or bulk carriers, we are here to grow your business while at the same time ensuring more sustainable operations, providing agility and resilience and more than anything: Keeping you empowered and competitive in the marine industry.
DEIF has become a preferred control solution supplier to the biggest operators in the market not just because of our innovative, safe and reliable technology but because of our commitment in guiding you through all phases of your project, from specification to configuration and commissioning.
DEIF’s flexible product platform covers the full range of application possibilities. Most customers are able to install and commission our standard products working from data sheets only. But in cases of doubt, DEIF’s far-reaching network of subsidiaries, distributors, customer care teams, and technical support teams is available to assist you and ensure you invest in and implement the best controller for your application.
Useful installation information can be found in the product quick start guide, and application setup is made easy with DEIF’s Utility Software. For greater detail, we refer you to the product installation instructions, just as you are invited to attend training courses on how to install and operate DEIF’s standard controllers.
Waste Heat Recovery can reduce emissions, but do you have enough power?
Engineered solutions
If you have special requirements that our standard devices do not cover, we can develop an engineered solution that does. We follow your vessel from design to commissioning, making sure that you are getting the performance you need.
Protection against cyberattacks
Designing resilient systems plays a key role in defending against cyber pirates. DEIF devices come with features that help you achieve this goal. For example, all DEIF controllers must pass network storm tests, and our Remote Access Support offering only works if crews operate a physical switch, reducing the risk of unauthorised access.
Tested, certified, and class approved
All DEIF devices for marine and offshore applications come with a long list of international marine and class approvals, for example MED approval. They are known for reliability and longevity, even in harsh environments. None of this is a coincidence: We develop, design, and manufacture our devices to exacting quality standards, and we test them rigorously to ensure that they can withstand a wide range of adverse conditions.
Techsol Marine uses PPM 300 to ensure safety at sea
Safety is an important criterion for power management systems. To design and build reliable solutions, Techsol Marine has used DEIF devices since 2010 – in particular, the PPM 300 which Electrical Engineer Rémy Rodrigue describes as reliable, easy to configure, and easy to use. But Techsol Marine is also working to advance the green agenda – and again, the PPM 300 has the features to help the Canadian company.
Read our commercial vessel guide
-
Contact us to discuss your options
- 90 years of energy pioneering
- Manufactured at the highest standards
- Superior quality
- Unmatched service and support
- Made in Denmark
Insulation monitor, AC networks AAL-2
The insulation monitor AAL-2 - the features
The insulation monitor, AAL-2, from DEIF has a high number of features:
- Insulation monitoring of AC networks of up to 440 V AC
- 10 M or 1 M ranges
- Adjustable warning set point
- Delay to prevent unwanted warnings
Electronic Potentiometer for panel EPQ96-2
- Control of electronic speed governors
- Setting of integrating time (like variable gearboxes)
- Adjustment of output signal
- Offset adjustment
- Manual/auto mode
- Analogue and digital output
- Converts a J1939 CAN input to an analogue or a PWM output
- Q96 panel mounting
Synchronisation & circuit breaker closing FAS-115DG
- Automatic.
- Voltage regulation
- Breaker-time compensation.
- Synchronisation of generator to busbar
- Circuit breaker time compensation
- Voltage control
- LED indication of status
- LED for activated control
- LED for synchronising signal
- 35 mm DIN rail or base mounting
Flexible current transformer FCT
- The flexible current transformer is designed for easy integration in a variety of applications and systems
- Ideal for power quality monitoring
- ≤ 1% Maximum measurements error (of final range value). MIC-2 MKII FCT and MIC-2 MKII FCT DIN including flexible current transformer
- Wire lead length 2 meters included
- Coil diameter 15.5mm
Multi-differential relay MDR-2
- Short response time (70 ms)
- 3-phase current detection on both generator sides
- Active adjustment of non-balanced current measurements
- Measuring accuracy 1 %
- Display indicator for all measurements
- DIN rail or base mounting with remote mountable display
Combined kWh counter and power meter WQR96 MKII, WQR96-x MKII & WQR96-c MKII
- Accuracy class 1.0 (EN 62053-21)
- For single-phase and 3-phase net-works
- Microprocessor-controlled meters with pulse output (SO)
- Simultaneous measurement of two quantities (except type WQR96 MKII)
- Scale: customised and exchangeable scale
- 60 to 400 V AC aux. power supply
Integrated systems DM-4 marine
- Internal system supervision
- Engine control, monitoring and protection
- 3-phase generator protections
- Automatic synchronisation
- Load sharing
- Dual ARCnet bus communication lines for redundancy
- Multiple display units and multiple Advanced Operator Panels
- Interface to the DEIF advanced graphical touch screen AGI
- 2 × Integrated RS-485 Modbus communication port
- 2 × CAN bus port for J1939 engine supervision, CANopen
- USB port for service software
- Up to 690 V AC direct AC inputs
- Alarm and event log
- Advanced load-dependent start/stop calculations
- Blackout prevention and recovery
- Priority selection
- Heavy consumer handling
- Base load function
- Trip of non essential load groups (preferential trip)
- Advanced fuel optimisation features
- One-touch auto sequences
- Dynamic positioning (DP-2) operation with closed bus tie breaker
- Fast dynamic load-share deviation protection
- Fast thruster load reduction
- Optimised load sharing
- 1 × Modbus TCP/IP
- Service software via ethernet for remote access
Multi-instrument MIC-2 MKII DIN
- Measures voltage, current/active/reactive and apparent power, frequency, energy kWh/kvarh, PF, THD, demand
- For all 2- and 3-phase AC network topologies
- Suitable for Power quality analysis
- Measures Individual Harmonics from 2nd to 63rd
- Min./max. statistic with time stamp
- Customised alarm settings with 16 different parameters
- RS-485 Modbus communication
- Large LCD screen with white backlight
- Optional communication modules - Ethernet (Modbus TCP, HTTP, SMTP) - Profibus DP
- Optional I/O modules - Relay - Analogue I/O - Digital I/O
- Free utility software with data logging
- Type approvals from all major classification societies
MTR-4 Multi-transducer MTR-4
- Suitable for all 1- and 3-phase network topologies
- Up to 1,000 VL-L AC input
- Accuracy class: 0.5 or 0.4
- Up to 4 analogue outputs
- Fast response time, less than 50 ms
- Measures more than 50 parameters
- RS-485 serial Modbus communication
- Fully configurable by USB, no aux. supply required
- Universal power supply of 20 to 300 V DC/48 to 276 V AC
Medium Voltage Relay MVR-200 series
- Programmable logic
- Fast and easy commissioning and service with front communication port and intuitive software
- Password-protected user levels
- Individual voltage and current harmonics up to 31st
- Redundant Ethernet with Modbus TCP
- RS-485 Modbus RTU communication
- IEC 60870-5-104/103/101 communication
- IEC 61850 communication (incl. HSR, PRT, PTP acc. IEEE 1588) and GOOSE
- On-site replaceable spare part modules
- Class 0.5 power and energy measurement (Class 0.2S optional)
- Conformal Coating available for all devices
- Marine type approval by major class societies
Undervoltage and overvoltage relay, U< and U> RMV-112D
- Under- and over-voltage.
- U>: 100 to 120 %, U<: 80 to 100 %.
- Under-voltage/over-voltage (U< + U>)
- ANSI code 27 and 59
- 3-phase measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting
Rudder angle transmitter RTA & RTC
- Analogue.
- 2 wire 4 to 20 mA DC.
- Ø19mm stainless steel shaft for direct rudder connection.
- Available with 90 ° mounting bracket
- Directly compatible with DEIF’s RT-2 rudder angle transmitter.
- Suitable for rudder, azimuth and pitch angle
- “No touch” magnetic angle detection – no wear & tear
- Accuracy < 0.25 °
- Analogue or CAN bus output for direct connection of one or more indicators
- Angle position range from +/- 20 ° to +/-180 °
- Continuous shaft rotation
- Clockwise/counterclockwise, zero set & max./min. adjustment
- MED approved
- CAN with 16 bit resolution (+/-180 degrees = +/-32767)
Insulation monitor, AC/DC-networks SIM-Q MKII
- Three functions: Normal, fast and test
- Easy set-point
- Leakage capacitance up to 2000 uF
- Measuring voltage up to 690 V AC and up to 1000 V DC
- AUX voltage: 24 V DC or selectable AC voltage from 100 to 480 V
- Measurement down to 5Hz (LF-version)
- Complies with IEC 61557-8
Multi-function synchroscope CSQ-3
Multi-function synchroscope meter - Features
The multi-function synchroschope meter from DEIF has a long list of features:
- Multi-function precision LED synchroscope
- Easy push-button programming of all set points
- Very high user safety
- High immunity to harmonic distortion
- Dead-bus functionality
- Voltage measurement
- Frequency matching
- Phase angle comparison
- DIN standard size: Q96
DC power supply DCP2 (24V)
- Automatic and electronic protection features
- Automatic restart after fault conditions
- Automatic output power derating for high ambient temperatures
- Green LED indication for aux. power connected
- Current output up to 40 A
- Adjustable output voltage
- No moving parts – no maintenance
- DIN rail-mounted
Loss of mains relay LMR-122D
- Vector shift and df/dt (ROCOF)
- Detection of vector shift
- ANSI code 78
- Mains disconnection on mains failure
- Ensures no asynchronous reconnection
- LED indication of fault condition
- LED indication for activated relay
- 35 mm DIN rail or base mounting
Multi-functional protection relay MTR-4P
- Up to 1,000 V L-L AC voltage input
- Up to 20 A AC current input
- Accuracy class: 0.5
- Password protection
- Trip time typically below 50 ms
- Two-stage trip setting
- Start-up delay
- 13 different protection functions
- RS-485 serial Modbus communication
- Fast and simple commissioning and setup from M-set
- Universal power supply of 20 to 300 V DC/48 to 276 V AC
- Marine approval by GL/DNV
Protection & power management PPM 300 PPM 300
- Synchronization
- Marine certified Power Management - ABP: Advanced blackout prevention (32dg)
- PLC logic
- Engine and Generator protection
- Engine CANbus
- Rear mount
- Flexible Hardware
- Additional I/O racks (9 racks)
- Ethernet Ring connection for Power management
- Redundant breaker feedback
- Colour Display
- Emulation
- Marine approval
- Heavy consumer
- Fast load reduction
- Fuel optimisation
Undervoltage relay, U< and U< RMV-132D
- Under-voltage (double).
- U<: 80 to 100 %, U<: 80 to 100 %.
- Under-voltage/over-voltage (U< + U>)
- ANSI code 27 and 59
- 3-phase measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting
AC transducer for active or reactive power TAS-331DG
Transducer range, TAS 331DG - Features
The transducer range by DEIF has a long list of features
- Factory-configured transducer for power or reactive power measurement.
- Aux supply: from 57 to 690 V AC
- Aux supply: 24 to 220 V DC
- Class 0.5 measurement
- Supply and measuring voltage up to 690 V
- Pre-configuration or easy PC tool configuration
- Configurable up to three output slopes
AC transducer for U, I, PA, f TAS-311DG
- Factory-configured transducer for voltage, current, frequency or phase angle measurement
- Aux supply: from 57 to 690 V AC
- Aux supply: 24 to 220 V DC
- Class 0.5 measurement
- Supply and measuring voltage up to 690 V
- Pre-configuration or easy PC tool configuration
- Configurable up to three output slopes
Insulation amplifier TDG-210DG
- Converting one type of DC signal into another DC signal
- Converting potentiometer input into a DC signal
- Separating a number of earthing points
- Galvanic separation of current signals
- Conversion of measuring signal
- Adaption of measuring range
- Separation of measuring circuits
- Measuring on DC shunts
- Measuring of DC voltages
Power meter WQ
The power meter for power and reactive power from DEIF has a long list of features:
- 1.5 accuracy class
- 90 ° and 240 ° pointer deflection
- IP52 protection (IP54 on request)
- Measuring voltage: 100 to 110 to 127 to 220 to 230 to 240 to 380 to 400 to 415 to 440 V AC
- Measuring range: Frequency: 45 to 65 Hz
- Measuring current: direct or from C.T.-/1 A or -/5 A
- Scale: customised and exchangeable scale available for 90 °
Flexible display indicator for navigation applications Navigation Indicator (XDi-N)
- TFT graphical LED 3.5, 5 or 7" display
- Two CAN ports with CANopen and XDi-net
- Redundant power inputs
- XDi-Net – add multiple XDi indicators
- Up to six NMEA inputs & up to four outputs
- NMEA data offset and averaging functions
- Dimmer controllable using front/external pushbuttons, analogue, NMEA or CAN/XDi-net.
- 3 level priority data fall-back function
- True wind data calculation
- Calculate magnetic or true heading
- XDi-net group dimmer and day/night colour shift
- Toggle between up to four predefined indicator screens using the mode function
- Quick-switch between measuring units either locally or for the entire system
- Customised indicator designs available on request
- Standard day and night designs, dusk on request
- Optional analogue or digital inputs
- Optional warning and alarms/relay output
- MED and other relevant class approvals
Synchronisation & circuit breaker closing FAS-113DG
- Automatic.
- Voltage regulation
- Breaker-time compensation.
- Synchronisation of generator to busbar
- Circuit breaker time compensation
- Voltage check
- LED indication of status
- LED for activated control
- LED for synchronising signal
- 35 mm DIN rail or base mounting
Generator protection unit GPU 300
- Comprehensive generator/busbar protection
- Smart synchronization check
- Supervision
- High resolution 5" colour graphic display with push-buttons
- Flexible and modular input/output with metal rack
- Plug & play, auto-configure I/O modules and network
- Integrated 5 × RJ45 ports with auto-detected multi-function
- Access to all connected units in one point
- Context-sensitive help in the controller display unit
- Event and alarm log, with real-time clock
- Pre-defined control settings
- User-friendly logic configuration tool, based on ladder logic and function blocks with monitor operation
- Password-protected, with customisable permission levels
- 3-phase AC measurement, up to 690 V AC directly, class 0.5
- Easy-to-use PC tool (PICUS)
- Advanced alarm handling with latch and shelve possible
Current relay RMC-122D
- Short circuit and over-current
- I>>: 100 to 400 %, I>: 50 to 150 %
- Combined functionality
- Short circuit relay (I>>)
- ANSI code 50 and 51
- Measurement of 3-phase currents
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting
Overvoltage relay, U> and U> RMV-122D
- Over-voltage (double).
- U>: 100 to 120 %,U>: 100 to 120 %.
- Under-voltage/over-voltage (U< + U>)
- ANSI code 27 and 59
- 3-phase measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting
AC transducer for bi-directional current and power TAS-321DG
- Factory-configured transducer for bidirectional current measurement.
- Aux supply: from 57 to 690 V AC
- Aux supply: 24 to 220 V DC
- Class 0.5 measurement
- Supply and measuring voltage up to 690 V
- Pre-configuration or easy PC tool configuration
- Configurable up to three output slopes
Panorama rudder indicator TRI-2
Rudder indicator - Features
The rudder indicator from DEIF has a long list of features:
- Analogue input
- 3 extra large, easy-to-read scales
- Readable from up to 5 meters
- Black or white scales
- Long-life LED illumination
- Built-in dimmer
- Analogue interface or CAN
- MED approved scales where applicable
Wind sensor WSS 750
Wind sensor, WSS 750 - features
DEIF's wind measuring devices from the WSS 750 series have a long list of features:
- Well-suited for dynamic positioning systems
- All stainless steel construction
- High power ultrasonic transducers in an equalsided triangle constellation
- No moving parts; no wear
- Wind speed up to 65 m/s (120 Knot)
- Speed accuracy better than 3 % (min. +/-0.2 m/s)
- Direction accuracy better than +/- 2°
- NMEA protocol
- IP66 and IP67 full waterproof
- DNV GL approved
Advanced graphical interface AGI 400
- Wide screen format
- True glass front
- Capacitive touch screen
- Multi-touch and Gestures
- Robust aluminium housing
- SD card slot for easy storage and updating
- USB hosts for printers, accessories, data storage and updating
- Dimmable LED backlight
- Web server for remote access from i.e. mobile devices
- 3 Ethernet ports with integrated switch
- Serial communication (RS-232, RS-422 and RS-485)
- Wide range of support for industrial protocols
- OPC UA Server and Client
- JAVA scripting
- CODESYS V3 (optional)
- Powerful ARM Cortex-A9 processor
- Plug-in module for CANbus (CANopen/J1939)
- Wide operating temperature -20°C to +60°C
- Marine certifications
- Certified for hazardous environments
- Available in 7", 10", 15" and 21" sizes
Current relay RMC-131D
- Differential current relay
- ANSI code 87
- Measurement of 3-phase currents
- Non-stabilised measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- Extra change-over relay contact for signalling
- 35 mm DIN rail or base mounting
Over-/undervoltage relay, U> and U< RMV-142D
- Under- and Over-voltage.
- U>: 100 to 120 %, U<: 80 to 100 %.
- Single phase measurement.
- Under-voltage/over-voltage (U< + U>)
- ANSI code 27 and 59
- 3-phase measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting
DEIF utility software USW-3
Utility software, USW-3 - Features
USW-3 is a utility software with a long list of features:
- Graphical tool for plant single line diagram
- Set controller parameters and configure advanced logic
- Configure controller I/O and external I/O equipment
- Translation of controller display texts
- AOP push-button configuration
- Controller firmware upgrade
- Security and access configuration
- Save/restore the entire plant setup to files
- User platform for emulation solutions
- Visualise dynamic plant and individual genset behaviour
- Display of all engine data
- Display of all electrical data
- Monitor the dynamic behaviour of measurements
- Display of fuel consumption and power production
- Emulate various external events
- Alarm monitoring
- Localised to English, Russian and Chinese
- Connects over USB, RS-485 or TCP/IP to controllers
Touch screen wind alarm system WAU 100
Wind alarm system WAU 100 - Features
The wind alarm by DEIF has a list of many features:
- NMEA0183 input
- 1 channel for MWV (wind)
- 1 channel for UTC time (ZDA or RMC)
- Easy installation, simple wiring
- Touch screen
- Wind data and alarm are logged
Flexible display bridge indicator XDi
Illuminated display indicator features
- TFT graphical LED 3.5, 5 or 7" display
- Multiple virtual indicator layouts selectable from library
- Standard and custom scale designs
- Displays 1 or more values
- 96, 144 or 192 DIN cutouts
- XDi-Net – a short-cut to CAN bus
- Reduced wiring and installation
- Instant repairs on board
- MED and other relevant class approvals
Analogue illuminated bridge indicator XL
Illuminated panel indicators - Features
The illuminated panel indicators has a long list of features:
- High shock/vibration resistance (robust)
- Class 0.5 accuracy
- 360 ° deflection
- Analogue or dual CANopen interface
- Optional IP66 protection
- LED illumination panel
- Q72, Q96, Q144 and Q192 scale sizes
- MED approved scales where applicable
Wind sensor WSS 550
Wind measuring instrument - WSS 550 - features
The wind measuring instrument from DEIF has a long list of features:
- Measures wind speed and direction
- IP66 housing
- Intelligent heating prevents icing up
- Working temperature down to -40 °C
- Well-proven and robust technology
- Advanced system integration with XDi-N
- Plug’n’play replacement for WSS/WSS-L
- Fully compatible with WSDI-2 indicators
- DNV GL approved