The main changes implemented since the last version are as follows:

New Features

  • Support for hardware changes.
  • Bug fixes.
Ver. Date Description

1.0.829

19/12/2022

New Features

  • Support for hardware changes.
  • Bug fixes.

1.0.756

04/03/2022

New Features

  • Supports new Ethernet second source AGI407/AGI410/AGI415/AGI421.
  • Removed FPGA configuration in system settings for products with new Ethernet component.

1.0.741U25

13/01/2022

New Features

  • Add support for DCC, Device Compatibility Code as improvement of BSP upgrade/downgrade process (DCC is stored in devices at manufacturing time)
  • Streamline BSP upgrade/downgrade with the use of DCC, Device Compatibility Code
  • Support new eMMC second source AGI 415/AGI 421
  • Support new USB HUB second source AGI 407/AGI 410/AGI 415/AGI 421
  • Enable autocalibration for touch screen
  • Application management in System Settings
  • Add support for forwarding rules on VPN, PPP and bridge interfaces
  • Add Spanish, Portuguese/Brazilian, Russian language
  • Added option to execute script autoexec.sh when SD is inserted
  • Add Korean and Traditional Chinese languages
  • Fixing support for projects larger than 240MB with Manage Target
  • Add access to OSS license information on BSP components in system settings
  • Add Japanese language
  • Add custom font management to System Settings for apps (Chromium, CODESYS)
  • Add mapping of USB to Serial interfaces to ttyS for use with CODESYS
  • Chromium - Minor issues in dialogs with small screens

Corrections/Improvements

  • BSP update occasionally fails updating mainos and configos
  • Local and Browser randomly reload System Settings pages also while user is editing
  • “Restore settings” will reset default values of fast boot, HW switch
  • Error uploading OpenVPN file config from browser
  • Error appearing during configuration via browser while connecting directly HMI to PC
  • NTP client and NTP server can be activated separately
  • CODESYS applications should be launched with read-write data partition in fast boot mode
  • Tap-tap not working when we enable fast boot
  • MAC address not returned correctly on bridged interfaces

Security Updates

  • Missing charset in Content-Type Fix to avoid potential attack by UTF-7 XSS
  • Update OpenVPN version for security reasons
  • Added https CA-certificates for Chromium app
  • Disable incoming NTP mode 6 queries
  • Cybersecurity fix CVE
  • Avoid DHCP spoofing vulnerability by not listening on TAP interface
  • Cyber Security: Web Server Error Page Information Disclosure
  • VNC Server crashes if malformed packets are sent
  • Update u-boot to version 25 to prevent display to be blank after sw reboot

1.0.741

22/12/2021

New Features

  • Add support for DCC, Device Compatibility Code as improvement of BSP upgrade/downgrade process (DCC is stored in devices at manufacturing time)
  • Streamline BSP upgrade/downgrade with the use of DCC, Device Compatibility Code
  • Support new eMMC second source AGI 415/AGI 421
  • Support new USB HUB second source AGI 407/AGI 410/AGI 415/AGI 421
  • Enable autocalibration for touch screen
  • Application management in System Settings
  • Add support for forwarding rules on VPN, PPP and bridge interfaces
  • Add Spanish, Portuguese/Brazilian, Russian language
  • Added option to execute script autoexec.sh when SD is inserted
  • Add Korean and Traditional Chinese languages
  • Fixing support for projects larger than 240MB with Manage Target
  • Add access to OSS license information on BSP components in system settings
  • Add Japanese language
  • Add custom font management to System Settings for apps (Chromium, CODESYS)
  • Add mapping of USB to Serial interfaces to ttyS for use with CODESYS
  • Chromium - Minor issues in dialogs with small screens

Corrections/Improvements

  • BSP update occasionally fails updating mainos and configos
  • Local and Browser randomly reload System Settings pages also while user is editing
  • “Restore settings” will reset default values of fast boot, HW switch
  • Error uploading OpenVPN file config from browser
  • Error appearing during configuration via browser while connecting directly HMI to PC
  • NTP client and NTP server can be activated separately
  • CODESYS applications should be launched with read-write data partition in fast boot mode
  • Tap-tap not working when we enable fast boot
  • MAC address not returned correctly on bridged interfaces

Security Updates

  • Missing charset in Content-Type Fix to avoid potential attack by UTF-7 XSS
  • Update OpenVPN version for security reasons
  • Added https CA-certificates for Chromium app
  • Disable incoming NTP mode 6 queries
  • Cybersecurity fix CVE
  • Avoid DHCP spoofing vulnerability by not listening on TAP interface
  • Cyber Security: Web Server Error Page Information Disclosure
  • VNC Server crashes if malformed packets are sent

1.0.535

06/09/2020

New Features

  • Firewall support
  • NAT/Forward service support
  • Zero dimming enhancement AGI 410 
  • Enable NTP local time reference clock

Corrections/Improvements

  • Improved event behavior when touchscreen is disabled
  • Cursor may not appear at boot with some mouse devices
  • 800Kbit CAN baudrate support
  • Improved Ethernet messages in case of high network traffic 
  • Software bridge not working via API
  • Screen remains black after toggling external timeout variable

 

1.0.344

22/01/2019

Corrections/Improvements:

  • Handle dbus init script remove in migrations.
  • US03 xsplash event loop rolled back (prior to infinite progress implementation).
  • Run xscreensaver before AGI project (backlight disable not working with fastboot).
  • Reset WIFI configuration when Network Settings are restored.
  • Fix udev mouse events not triggered if a mouse is plugged in before power on.
  • UN6x - Mouse cursor is shown on some applications when a mouse is not plugged in.
  • Import cryptodev from master (required by new OpenSSL).
  • OpenSSL 1.0.2n: upgrade and patches ported.
  • Recipe compatibility fixes for OpenSSL update.
  • Grabbed python recipes from master (for updated hashlib APIs based on new openssl).
  • Grab latest openssl and openssh recipes from master.
  • Grabbed OpenVPN 2.4.4 recipes from meta-open embedded/master.
  • Added openssl-backcompat package with OpenSSL 1.0.1e binaries.
  • OpenSSL config file fix.
  • OpenSSH 7.6.
  • Update to OpenVPN 2.4.4 and custom_control_message patch alignment.
  • Start ntpd daemon with unsync status.
  • Add openssl-backcompat to image.
  • Remove warning when enabling SSH service.
  • Set PREFERRED_VERSION_openssl = 1.0.2n.
  • Hide rpine0 interface from System Settings.
  • Add support recipes from meta-fsl-arm to support video codecs on us03.
  • Add support for us03 video codecs.
  • UN71 - Rename bootloader version tag to B03D and B03Q.
  • uS03-jsxx Edited Wifi reset support.
  • uS03-jsxx Added Wifi reset support.
  • Change "RAM Size" to "Toatal Available RAM".
  • us03 has two different bootloaders, b03d and b03q.
  • Fix syslog not starting when fastboot and persistent log are both enabled.
  • Generate certificate files if missing.

 

1.0.195

15/09/2017

New features:
1. Add set LCD colour correction if needed
2. Fastboot support for future Creator version 

Corrections/Improvements:
1. Device Names visible in Codesys V3 are partly wrong, partly incoherent
2. Screen can not be calibrated after orientation change
3. Restore touchscreen calibration from udev after USB touch unmount/remount
4. Do not preserve settings if version differs in major or minor number
5. Don't set interface speed via ethtool if it remains unchanged
6. Give admin permission to access sdcards
7. Add input validation to network settings
8. Trigger failure upon networkmanager errors and more consistent EPAD API Corrections
9. Bridge: use configuration of first interface by default
10. Space button disapperars in Vkeyboard when shift is active
11. Disable Avahi Service by default
12. Users cannot browse OpenVPN configuration files from panel
13. AutoIP mode doesn't work on Bridge
14. Add a tool to take screenshots for internal automatic tests (xwd)
15. Exit command from System Settings menu accessed via browser causes credential request in endless loop

 

On this page, you can download software updates for your product(s) and help yourself to various utility tools and add-ons that will assist you in setting up, detecting faults and configuring your product(s).

Please be advised that not all of our products can be updated by the user. Nor do all of our products come with a utility tool. Consequently, the list on this page cannot be considered an overview of our product programme.

DEIF will register your download along with the used e-mail address for the purpose of sending out information on future updates, if requested.

DEIF cannot be made responsible for any consequences of failed product updates or use of utility tools. Nor can DEIF A/S be made responsible for consequences of changes in behaviour of products due to a software upgrade. It is always the responsibility of the user to ensure correct set-up and configuration before commissioning. Please study the version log of the software before updating the product.

Licence agreement for software downloaded from www.deif.com

Downloaded software remains the property of DEIF. The software may not be distributed for commercial purposes, changed or reused in full or in part or sold to any third parties.

The latest versions for full functionality

As always, we recommend that you install our offered improvements to fully utilise your DEIF product.

All improved software can be downloaded at your convenience at www.deif.com under “Software”.

Should you have any questions or experience problems finding the relevant software for your product, please feel free to call DEIF A/S at +45 96149614 or your relevant local DEIF office. Alternatively, we are always ready to assist you, if you send an e-mail to support@deif.com.