Full gas engine control
Retrofits are one of our core competencies. Replacing existing OEM genset controllers with 1:1 conversions or according to customer specifications, we can have an entire system up and running in just a few days.
Control all types, makes and sizes
Efficiently and regardless if your gas is bio, natural, landfill or other, our control solutions will enable you to convert it into energy like no other systems. The size of your application is not an issue for us. Nor is the type and make of your gas engine or turbine.
Costs down – value up
DEIF solutions are designed to optimise operation and reduce gas consumption. Your expenses will drop from day one. You will always be backed by a team of experienced service and support engineers.
You name it – we develop it
DEIF’s standard controllers are extremely flexible and will accommodate most of your needs. But we are also happy to develop completely unique solutions designed exclusively for your specific application. The solutions are subject to continuous review and approval by our quality-conscious customers.
Insulation monitor, AC networks AAL-2
The insulation monitor AAL-2 - the features
The insulation monitor, AAL-2, from DEIF has a high number of features:
- Insulation monitoring of AC networks of up to 440 V AC
- 10 M or 1 M ranges
- Adjustable warning set point
- Delay to prevent unwanted warnings
Automatic sustainable controller ASC plant management
- Maximising PV penetration
- Spinning reserve demand
- Minimum genset load requirement
- Suitable for self-consumption and IPP applications
- Support of SunSpec and other relevant protocols
- Monitoring and supervision
- Meteorological measurements
- Fully integratable in AGC Power Management applications
- Simple graphical configuration
- Record time commissioning with DEIF Emulation – uses and verifies the functions of the real system for test, production and design
- Suitable for power management solutions fitted with AGC PM genset controllers
- Suitable for stand-alone solutions using multi-instruments such as DEIF’s MIB or MIC
Data Acquisition Unit FX-30
Data Acquisition Unit
- Event-based logging
- Updates Over-the-air (OTA)
- 3G UMTS/HSPA+
- 2G Edge/GSM/GPRS
- 1 communication LED, 1 signal LED
- GNSS (GPS/Galileo/Glonass)
- Ultra low power mode
- Ethernet (RJ-45) for Modbus TCP/IP
Simple to install
- 3-way DIN rail clip orientation
- Fast IP configuration via micro USB
- Antennas and cables included
- High vibration mounting
Electronic Potentiometer for panel EPQ96-2
- Control of electronic speed governors
- Setting of integrating time (like variable gearboxes)
- Adjustment of output signal
- Offset adjustment
- Manual/auto mode
- Analogue and digital output
- Converts a J1939 CAN input to an analogue or a PWM output
- Q96 panel mounting
Synchronisation & circuit breaker closing FAS-115DG
- Automatic.
- Voltage regulation
- Breaker-time compensation.
- Synchronisation of generator to busbar
- Circuit breaker time compensation
- Voltage control
- LED indication of status
- LED for activated control
- LED for synchronising signal
- 35 mm DIN rail or base mounting
Generator paralleling controller GPC-3 gas
- Mains/Generator/Motor protection
- The unique M-Logic, a simple configuration tool
- Engine protection with backup on shutdown channels
- Governor and AVR control
- J1939 engine com/mirrored Modbus/Profibus/TCP/IP
- Multible display units and operator panels possible
- Additional Operator Panel (AOP)
Insight
- Visualised solution overview via customisable dashboard
- World map overview and GPS tracking
- Alarm notifications (email)
- Reports (PDF, CSV)
- Fleet management (unit grouping & scheduling)
- Flexible user/team management and user permissions
- Two factor verification for enhanced security
- Templates for selected DEIF products
Dashboards widgets
- Direct value visualisation
- Multiple options of guages
- World map overview
- Group data in lists
- Show latest notifications
- Trending with graphs
Responsive web service
- Designed for portable devices
- Works with most popular browsers
- Requires Insight subscription plan
Multi-differential relay MDR-2
- Short response time (70 ms)
- 3-phase current detection on both generator sides
- Active adjustment of non-balanced current measurements
- Measuring accuracy 1 %
- Display indicator for all measurements
- DIN rail or base mounting with remote mountable display
AC transducer for U, I, PA, f TAS-311DG
- Factory-configured transducer for voltage, current, frequency or phase angle measurement
- Aux supply: from 57 to 690 V AC
- Aux supply: 24 to 220 V DC
- Class 0.5 measurement
- Supply and measuring voltage up to 690 V
- Pre-configuration or easy PC tool configuration
- Configurable up to three output slopes
Automatic Load Controller ALC-4
- Prioritised load groups
- Anticipated load-dependent start
- Integrated in power management system
- Automatic startup of extra gensets
- Avoid overload of system
- Manual or automatic control of feeders
- Easy setup via USW and intuitive to use
- Easy commissioning, prepare SW setup before commissioning, live status of feeders shown in USW
- Flexible setup of different application types
- CANbus communication, long distance communication (up to 300 m)
- Security of supply – safety based on feeder priority
Medium Voltage Relay MVR-200 series
- Programmable logic
- Fast and easy commissioning and service with front communication port and intuitive software
- Password-protected user levels
- Individual voltage and current harmonics up to 31st
- Redundant Ethernet with Modbus TCP
- RS-485 Modbus RTU communication
- IEC 60870-5-104/103/101 communication
- IEC 61850 communication (incl. HSR, PRT, PTP acc. IEEE 1588) and GOOSE
- On-site replaceable spare part modules
- Class 0.5 power and energy measurement (Class 0.2S optional)
- Conformal Coating available for all devices
- Marine type approval by major class societies
Advanced Genset Controller AGC 150 BTB
AGC 150 BTB - features
- Automatic close of bus tie breaker if the system requests help
- Manual control of bus tie breaker
- Section management
- 12 Digital inputs and 12 digital outputs
- Communications ports (CAN, USB, RS485, Ethernet).
- Event & alarm log (500 each)
- Programmable PLC editor
Automatic genset controller AGC plant management
- Fully scalable multi-master system of up to 992 gensets
- Simple graphical configuration
- Easy control from one central point of intelligence
- Cost-optimised design
- Reduced fuel consumption
- Grid support
- Monitoring and supervision
- Emulation Solution – uses and verifies the functions of the real system for test, production and design
- Suitable for hybrid power solutions fitted with ASC PM controllers
Multi-functional protection relay MTR-4P
- Up to 1,000 V L-L AC voltage input
- Up to 20 A AC current input
- Accuracy class: 0.5
- Password protection
- Trip time typically below 50 ms
- Two-stage trip setting
- Start-up delay
- 13 different protection functions
- RS-485 serial Modbus communication
- Fast and simple commissioning and setup from M-set
- Universal power supply of 20 to 300 V DC/48 to 276 V AC
- Marine approval by GL/DNV
Advanced Genset Controller AGC 150 Generator - Stand alone
- RS485
- PLC logic
- Inputs/ Outputs
- Analog Inputs / Analog Outputs
- Analog inputs support resistance, current and voltage
- AOP 2 support
- Emulation for easy training and FAT
- UL approved
- Automatic Mains Failure sequence
- Tier4 final / Stage V
- Emission control with force regeneration and SOOT alarm
- Fuel pump logic (after filler)
- Changable operation mode (multiple modes in one software)
- Adapting controls (Controllers show only relevant buttons)
- Front mount
- DEIF digital AVR DVC550 support
- Additional I/O modules support (CANbus based CIO)
- Engine CANbus
- Engine and Generator protection
- -40 degree support
- Ethernet
- USW
- USB
Digital voltage controller DVC 550
- Unique CANbus integration between DVC 550 and AGC genset controller
- Start management capability with start on threshold, soft start and close before excitation (run-up sync)
- Intelligent drying and ventilation mode for generators
- Short circuit limitation
- Loss of voltage sensing alarm
- Over/under excitation limitation
- Optimises genset performance and size using engine help functions
- Load acceptance module (LAM) assists the generator during heavy loads
- Negative forcing to avoid voltage peak during load sheddin
- U/F ramp
- Soft voltage recovery
- Stator current limitation
- Settings from AGC genset controller shared with the DVC 550 via CANbus
- Grid code compliant VDE410 and VDE4105
Touch display units for asset and plant management TDU series
- Plug and play
- Build in AOP (additional operators panel) customizable buttons and status lamps
- Quick instrument selection directly from the screen
- Tier 4 Final support with automatic jump to dedicated Tier4 page
- Visual capability curve with actual working point of the genset
- Easy search functionality in several menus
- Live application supervision
- Possibility to merge alarm and event logs
- Service menu with estimated date for next service
- Live I/O overview
Advanced graphical interface AGI 400
- Wide screen format
- True glass front
- Capacitive touch screen
- Multi-touch and Gestures
- Robust aluminium housing
- SD card slot for easy storage and updating
- USB hosts for printers, accessories, data storage and updating
- Dimmable LED backlight
- Web server for remote access from i.e. mobile devices
- 3 Ethernet ports with integrated switch
- Serial communication (RS-232, RS-422 and RS-485)
- Wide range of support for industrial protocols
- OPC UA Server and Client
- JAVA scripting
- CODESYS V3 (optional)
- Powerful ARM Cortex-A9 processor
- Plug-in module for CANbus (CANopen/J1939)
- Wide operating temperature -20°C to +60°C
- Marine certifications
- Certified for hazardous environments
- Available in 7", 10", 15" and 21" sizes
Advanced Genset Controller AGC 150 Mains
AGC 150 Mains - features
Operating modes with single or multiple mains:
AMF, Fixed power, Mains power export Load take over, Peak shaving
- Mains (Utility)
- power monitoring (kW, kV, A & pf)
- decoupling protection
- kW export protection
- electrical protections
- No break transfer of load
- Multi start settings
- Minimum of starting genset
- 12 Digital inputs and 12 digital outputs
- Communications ports (CAN, USB, RS485, Ethernet).
- Event & Alarm log (500 each)
- Programmable PLC editor